BT-750 (Multi Parameter Patient Monitor

27

Product Information:

Model: BT-750

Brand: Bistos

Made In Korea

Features:

  • Selectable 6 wave / 5 wave / 4 wave / 3 wave Display.
  • Up to 3 hours use with a battery.
  • Quick Start-Up: 72 hours of tabular and graphic trend data.
  • RS-232 port or LAN.
  • Multi-national Languages (7 languages).
  • Central Monitoring System (UDP type).

Specifications:

  • Display Model: IP-4050 10.4″ wide TFT color LCD.
  • Dimensions: 257 cm (W) x 236 cm (H) x 158 cm (D).
  • Weight: 3.0 kg (excluding accessories).
  • Resolution: 800 x 480 pixels.
  • Waveforms: 6 max.
  • Power Requirements:

o    Voltage: AC 100 – 240 V / 50/60 Hz / 100 VA.

o    Battery: One battery typically provides operating time of 3 hours per when fully changed with no printing, no external communication, and no audible alarm sound.

o    Battery type: Li-ion (11.1 VDC / 220 mAH).

o    Fuse: 250 V / 5 A.

  • Environmental Conditions:

o    Operating Temperature: 50 to 104 °F.

o    Operating Humidity: 15 to 90% RH, non-condensing.

o    Storage Temperature: -4 to 122 °F.

  • ECG:

o    LEAD: 3/5 leads, I, ii, iii, aVR , aVL, aVF, V (Chest Lead).

o    HR (Heart Rate) Measurement Range: 20 to 300 bpm.

o    HR Range Accuracy: ± 3 bpm or ± 3%, whichever is greater.

o    Sweep Speed: 1.25 cm/s, 2.5 cm/s, 5 cm/s.

o    Lead-Off Detection: Yes.

o    CMRR: > 90 dB at 50 or 60 Hz.

o    Gain: 0.5, 1, 2 cm/μ V.

  • Temperature Measurement:

o    Method Type: Thermistor.

o    Compatible With: YSI Series 400 Temperature Probes.

o    Range: 50 to 113 °F.

  • Display Accuracy:

o    ± 32.18 °F.

o    ± 32.36 °F (Less than 77° F).

  • Respiration:

o    Method Type: Trans-thoracic impedance.

o    Leads: RA to LA.

o    Range: 0 to 150 breaths/min.

o    Accuracy: ± 2 breaths/min.

o    Sweep Speed: 0.625 cm/s, 1.25 cm/s, 2.5 cm/s.

  • NIBP:

o    Measurement Technology Oscillometric method.

o    Pressure Display Range: 0 to 300 mmHg.

o    Pressure Display Accuracy: Less than ± 3 mmHg.

o    Measurement Range (Adult / Child):

  • Systolic: 50 to 225 mmHg.
  • Diastolic: 30 to 220 mmHg.
  • Mean: 40 to 235 mmHg.

o    Measurement Range (Infant / Neonate):

  • Systolic: 30 to 130 mmHg.
  • Diastolic: 20 to 100 mmHg.
  • Mean: 25 to 120 mmHg.

o    Measurement Mode: Manual, Auto, STAT.

o    Auto Mode: 1, 3, 5, 10, 30, 60, 90, 120, 240 min.

  • SpO2: (Pulse Oximeter):

o    Saturation Range: 0 – 100%.

o    Pulse Rate Range: 20 to 300 bpm.

o    SpO2 Accuracy:

  • Adult: 70 to 100% ± 2%.
  • Neonate: 70 to 100% ± 3%.
  • 0 – 69%: Unspecified.

o    Pulse Rate Accuracy: 20 to 300 bpm ± 2%.

o    Perfusion Range: 0.05 to 20%.

  • IBP:

o    Channel: 2 channels.

o    Method Type: Pressure transducer method.

o    Pulse Rate Range: 20 to 250 bpm.

o    Pulse Rate Accuracy: ± 1% or ± 1 bpm.

o    Pressure Measurement Range: -50 to 300 mmHg.

o    Parameter Displayed: P1, ABP, P2, CVP, PAP, LAP.

Give Shape to Your Vision